Error
Code
Description
210
Security value for a PDF417 bar code is outside the
range 0 to 8. Correct the value and resend the
format to the printer.
211
Narrow element value is less than 2 or greater than
99. Correct the value and resend the format to the
printer.
212
Wide element value is less than 2 or greater than 99.
Correct the value and resend the format to the printer.
213
Dimension is not within the correct range for the
row/column value:
1 to 30 for a column
3 to 90 for a row
214
Trunctation code is invalid. Valid options:
S
Standard bar code
T
Truncated bar code
215
Aspect code is invalid. Valid options:
C
Columns
R
Rows
216
Rule definition code is invalid. Valid codes:
S
Set
T
Template
E
rro
rs
Chapter 11. Errors
11-7