Defining bar code fields – Pitney Bowes J640 User Manual
Page 121

Defining Bar Code Fields ––––––––––––––––––––––––––––––––––––
Example
B,3,12,V,150,40,1,2,80,7,L,0
p
Syntax
B,field#,# of char,fix/var,row,column,font,
density,height,text,alignment,field rot
p
B1. B
Indicates bar code field. Enter B.
B2. field #
Unique number from 0-99 to identify this field. (Pitney
Bowes recommends starting at 1, instead of 0.)
B3. # of char
Maximum number of characters. Range: 1-2710.
B4. fix/var
Fixed or variable length field. Options:
F
Fixed length
V
Variable length field.
B5.row
Distance from bottom of print area to lower left corner of
the field. (The bottom exits the printer first.) Ranges:
English
0 - 599
Metric
0 - 1523
Dots
0 - 1151
B6. column
Distance to the lower left corner of the field from the left
edge of print area. Ranges:
English
0 - 399
Metric
0 - 1014
Dots
0 - 767
J640 Programmer’s Manual
7-6