Defining the communication settings record f – Pitney Bowes J640 User Manual
Page 150

Defining the Communication Settings Record F –––––––––––––––––
Changing the communication settings takes approximately two
seconds to complete. Communications during this interval
may be lost. Always make sure the communications values at
the host match the values on your printer, or you will not be
able to print formats.
Example
{I,F,3,0,0,0,0
p
}
Syntax
{I,F,baud,word_length,stop_bits,parity,
flow_control
p
}
F1. F
Indicates the Communication Settings Record
F2. baud
Options:
0
1200
1
2400
2
4800
3
9600 (default)
4
19.2K
F3. word_length
Options:
0
7-bit data frame
1
8-bit data frame (default)
F4. stop_bits
Options:
0
1-stop bit (default)
1
2-stop bits
F5. parity
Options:
0
none (default)
1
ODD parity
2
EVEN parity
F6. flow_control
Options:
0
None
1
DTR (default)
2
CTS/RTS
3
XON/XOFF
Syn
tax Q
u
ick Ref
e
ren
ce
Chapter 7. Syntax Quick Reference
7-35