beautypg.com

KVH Industries TracVision G8 User Manual

Page 98

background image

5. Disconnect the Molex connector from the RF PCB.

Figure 5-9

RF PCB

6. Using a

1

4

" nut driver/socket, remove the four #6-32

standoffs securing the RF PCB to the PCB module (see
Figure 5-9). Remove the old RF PCB.

7. Apply a drop of Loctite threadlocker to the screw ends

of the four standoffs and secure the new RF PCB to the
PCB module with the standoffs.

8. Reconnect the Molex connector that you removed in

Step 5, and reinstall the PCB cover that you removed in
Step 4.

9. Reattach the PCB module to the antenna frame using

the module’s four captive screws.

10. Reconnect the cables that you removed in Step 2. Be

sure to reconnect all cables in their proper positions.
Figure 5-6 on page 100 shows the proper connector
assignments.

54-0198

102

TracVision G8 Owner’s Manual - Guide to Technical Information

Molex

Connector

Standoffs

(x 4)