4. Using a
5
⁄
64
" allen key, loosen the two #8-32 set screws
securing the feed tube in the LNB/feed tube assembly
collar. Remove the feed tube.
Figure 5-27
Removing the Feed Tube
5. Remove the four #8-32 screws securing the LNB/feed
tube assembly to the reflector base (see Figure 5-25).
Remove the LNB/feed tube assembly.
6. Disconnect the motor cable from the skew motor.
Figure 5-28
Skew Motor and Belt
7. Using a 2.5 mm allen wrench, remove the four M3 cap
screws and #4 washers securing the motor to the
LNB/feed tube assembly (see Figure 5-28). Remove the
old skew motor.
54-0198
114
TracVision G8 Owner’s Manual - Guide to Technical Information
Pulley
Motor Hub
M3 Cap Screws
and #4 Washers
(x 4)
Motor Cable
Connector
Motor Cable
Skew Belt
Feed Tube
#8-32 Set
Screws (x 2)