Sharp AR-M257 User Manual
Page 95
69
TROUBLESHOOTING AND MAINTENANCE
5
4
Close the front cover and side cover.
Make sure that the
misfeed message is
cleared.
B: Misfeed in the fusing area
1
Open the bypass tray and the side
cover.
2
Press and pull it open gently on both
sides of the front cover.
3
Turn the roller rotating knob in the
direction of the arrow.
4
Lift the fusing unit release levers and
carefully remove the misfed paper.
5
If you were unable to remove the
misfeed in step 4, press down on the
fusing unit paper guide knob to open
the paper guide, and carefully remove
the misfed paper.
6
Close the fusing unit paper guide and
press down on the fusing unit release
levers.
7
Close the front cover and side cover.
Make sure that the
misfeed message is
cleared.
The fusing unit is hot. Do not touch
the fusing unit when removing
misfed paper. Doing so may cause a
burn or injury.
Roller rotating knob
Fusing unit release levers
Warning
• Do not touch the photoconductive drum
(green portion) when removing the misfed
paper. Doing so may damage the drum
and cause smudges on copies.
• Take care not to let unfixed toner on the
misfed paper soil your hands or clothes.
Caution
!Andromeda_copy_sec.book 69 ページ 2006年11月23日 木曜日 午後6時1分