Misfeed in the bypass tray, Misfeed in the machine – Sharp AR-M257 User Manual
Page 94
68
TROUBLESHOOTING AND MAINTENANCE
MISFEED IN THE BYPASS TRAY
1
Carefully pull the misfed paper out.
2
Open and close the side cover.
Make sure that the
misfeed message is
cleared.
The message can also
be cleared by opening
and closing the front
cover.
If the message is not
cleared, see "A. Misfeed
in the paper feed area".
MISFEED IN THE MACHINE
Determine the location of the misfeed and remove it appropriately as indicated below.
A. Misfeed in the paper feed area
1
Open the bypass tray and the side
cover.
2
Press gently on both sides of the front
cover and pull it open.
3
Carefully remove the misfed paper.
Turn the roller rotating knob in the
direction of the arrow to assist in
removing it.
Be careful not to tear the
misfed paper during
removal.
If paper is misfed here, go to
"A. Misfeed in the paper feed
area" (below).
If paper is misfed, go to
"B. Misfeed in the fusing
area" (p.67).
The fusing unit is hot. Do not touch
the fusing unit when removing
misfed paper. Doing so may cause a
burn or injury.
Do not touch the photoconductive drum
(green portion) when removing the misfed
paper. Doing so may damage the drum and
cause smudges on copies.
Roller rotating knob
Warning
Caution
!Andromeda_copy_sec.book 68 ページ 2006年11月23日 木曜日 午後6時1分