Temperature/Humidity Condition

y Maintain the consistent temperature and humidity.

*Temperature : 0

o

C – 45

o

C

*Humidity : 10% – 90% (non-condensing)

y Should be in a cool place not exposed to direct sunlight.

y During or after setting up the system, equip a fan in the room in order to maintain the system by

preventing dust from going into.

Grounding Condition

You have to consider the followings when performing grounding operation.

y The connection hole, connected with the SMG-3200 grounding conductor, should be connected

to the earth grounding through a fine earth-grounding medium.

y Overall, the power circulation status of the SMG-3200 system exposed electric conduction with

the metal face and the rectifier power plug’s grounding conductor should be exceedingly fine.

y A single contact point must be made to connect if the grounding of all of the exterior

supplementary equipment are connected to the system’s grounding.

y The SMG-3200 grounding conductor should never be connected with the pipe for the interior

power wire.

y Power and ground standard must follow the national standard, and the installation office should

check whether the standard is kept.

y Power and grounding standards should suit the national standard where this are certified by an

installation organization.