Packet operation, Other functions, Ddata speed – Icom IC-2800H User Manual
Page 74
70
15
OTHER FUNCTIONS
■
Packet operation
D
Data speed
For packet operation, the transceiver can be set to one of two
data speeds: 1200 bps (default) or 9600 bps.
q
Push [
(DISP)
SET] for 2 sec. to enter set mode.
• Push [CHG/L] if [(DISP) SET] is not displayed.
w
Push [
Y
] or [
Z
] to select the ‘Packet BPS’ item.
• Left-hand tuning dial can also
select the item.
e
Rotate the right-hand tuning
dial to select the desired
data speed.
r
Push [
ï
] to exit set mode.
q
Push [
F
SET] to enter set mode.
w
Push [
F
SET] or [
G
ENT] to select the ‘Packet
BPS’ item.
e
Push [
Y
] or [
Z
] to select the desired data
speed.
r
Push [
E
CLR] to exit set mode.
For 1200 bps operation—
• Disconnect the microphone plug from the microphone
connector during data transmission, otherwise the data
signal and voice signal are simultaneously transmitted.
For 9600 bps operation—
• When the transceiver is set for 9600 bps data transmis-
sion in set mode, the microphone signal is automatically
cut. Therefore, it is not necessary to disconnect the mi-
crophone plug from the connector in this case.
• When pushing [PTT] during data transmission, data trans-
mission is interrupted and voice signals have priority.
ï
Y
Z
SET
Auto Power-Off
OFF
Auto
1200
Long
1
Cooling Fan
Packet BPS
Squelch Delay
HM-90 Address
SET