beautypg.com

Auto repeater function, Repeater operation, Dfrequency range and offset direction – Icom IC-2800H User Manual

Page 35

background image

31

6

REPEATER OPERATION

Auto repeater function

(U.S.A. and Korea versions only)

The U.S.A. and Korea versions automatically activate the re-
peater settings (duplex ON/OFF, duplex direction, tone en-
coder ON/OFF) when the operating frequency falls within or
outside of the general repeater output frequency range. The
offset and repeater tone frequencies are not changed by the
auto repeater function, reset these frequencies, if necessary.

q

Push [

(DISP)

SET] for 2 sec. to enter set mode.

• Push [CHG/L] if [(DISP) SET] is not displayed.

w

Push [

Y

] or [

Z

] to select the ‘Auto Repeater’ item.

• Left-hand tuning dial can also select the item.

e

Rotate the right-hand tuning dial to select the auto repeater
function.
U.S.A. version:

• “Dup”

Activates duplex only.

• “Dup&Tone”

Activates duplex and tone.

• “OFF”

Auto repeater function is turned OFF.

Korea version:

• “ON”

Activates duplex and tone.

• “OFF”

Auto repeater function is turned OFF.

r

Push [

ï

] to exit set mode.

q

Push [

F

SET] to enter set mode.

w

Push [

F

SET] or [

G

ENT] to select the ‘Auto Re-

peater’ item.

e

Push [

Y

] or [

Z

] to select the auto repeater

function.

r

Push [

E

CLR] to exit set mode.

D

Frequency range and offset direction

• U.S.A. version

• Korea version

FREQUENCY RANGE

DUPLEX DIRECTION

145.200–145.495 MHz
146.610–146.995 MHz

“DUP–” appears

147.000–147.395 MHz

“DUP” appears

442.000–444.995 MHz

“DUP” appears

447.000–449.995 MHz

“DUP–” appears

FREQUENCY RANGE

DUPLEX DIRECTION

439.000–440.000 MHz

“DUP–” appears

ï

Y

Z

SET

Operation Beep

ON

OFF

OFF

OFF

Auto

Tx T.O.T.

Auto Repeater

Auto Power-Off

Cooling Fan

SET

B