Chapter 11 – Data Commands

Multi-Tech Systems, Inc. Wireless GSM/GPRS AT Commands (Document Number S000293I)

93

Bearer Type Selection +CBST

Description:

This command applies to both outgoing and incoming data calls, but in a different way. For an outgoing
call, the two parameters (e.g., and ) apply; whereas, for an incoming call, only the
parameter applies.

Notes:

For incoming calls, if is set to

T, only and the network offers NT only or vice versa. Then the

call is released.

The values 2 and 3 for the parameter are equivalent to the former values of 100 and 101.

Those values are managed for compatibility purposes, but they should no longer be used in the
new code (2 as former 100 and 3 as former 101).

Values:

0 (default) Autobauding

(modem

type:

none)

1

300 bps

(modem type: V.21)

2

1200 bps

(modem type: V.22)

3

1200/75 bps (modem type: V.23)

4

2400 bps

(modem type: V.22bis)

5

2400 bps

(modem type: V.26ter)

6

4800 bps

(modem type: V.32)

7

9600 bps

(modem type: V.32)

8

Specific

12

9600 bps

(modem type: V.34)

14(*)

1400 bps

(modem type: V.34)

65

300 bps

(modem type: V.110)

66

1200 bps

(modem type: V.110)

68

2400 bps

(modem type: V.110)

70

4800 bps

(modem type: V.110)

71

9600 bps

(modem type: V.110)

75(*)

14400 bps (modem type: V.110)

(*) This speed configures data and fax 14.4 kbps bearers.

No data compression is provided and only asynchronous modem is supported ( = 0).
Connection element

0

Transparent only

1 (default)

Non transparent only

2

Transparent preferred

3

Non transparent preferred

Syntax:

Command syntax: AT+CBST= , ,

Command

Possible responses

AT+CBST=?
Note: Test command

+CBST: (0-8,65,66,68,70,71),(0),(0-3)
OK
Note: Data 14,4 kbps not supported

AT+CBST=?
Note: Test command

+CBST: (0-
8,12,14,65,66,68,70,71,75),(0),(0-3)
OK
Note: Data 14,4 kbps not supported

AT+CBST=7,0,1
Note: Ask for a bearer

OK
Note: Bearer supported

AT+CBST?

Note: Current values

+CBST:7,0,1
OK
Note: Command valid

AT+CBST=81,0,0
Note: Ask for a bearer

+CME ERROR: 4
Note: Bearer not supported