32kHz Power Down Mode +W32K
Description:
This command allows the 32kHz power down mode to be enabled or disabled:
•
When power down mode is entered, the product uses a 32kHz internal clock during inactivity
stages (regardless of its nominal internal clock).
•
When enabled, power down mode is active after 1 to 15 minutes. The mode is not stored in
EEPROM: the command has to be repeated after a reset.
For additional information on power down mode, see Specification of Power Down Control via
RS232 in the Appendix.
Values:
0 Disable 32kHz powerdown mode
1 Enable 32kHz powerdown mode
Syntax: Command
syntax: AT+W32K=
Command
Possible responses
AT+W32K=1
Note: Enable 32kHz power down mode
OK
Note: 32kHz power down mode is enabled
AT+W32K=0
Note: Disable 32kHz power down mode
OK
Note: 32kHz power down mode is disabled
Change Default Melody +WCDM
Description:
This command allows a the selection of a manufacturer-specific melody. This default melody will be
played for any new incoming voice call, either on the buzzer or on the speaker.
Values:
0
No melody (
default)
1…10 Melody 1 to 10
0
Melody n°
Default.
1
Melody n°
Syntax: Command
syntax: AT+WCDM=
Command
Possible responses
AT+WCDM=0
Note: Select no melody
OK
AT+WCDM=5
Note: Select melody n°5
OK
AT+WCDM?
Note: Indicate the current melody
+WCDM: 5,0
OK
Note: Melody n°5 is currently selected, and the buzzer is
selected to play it.
RING
Note: An incoming call occurs, and the melody n°5 is played
on the buzzer.
AT+WCDM=,1
Note: Select the speaker to play the
melody on.
OK
AT+WCDM? +WCDM:
5,1
OK
Note: Now the speaker is selected to play the melody if an
incoming call occurs.