beautypg.com

Chapter 13 – specific at commands, Cell environment description +cced – Multi-Tech Systems MMCModem GPRS (MTMMC-G) User Manual

Page 107

background image

Chapter 13 – Specific AT Commands

Multi-Tech Systems, Inc. Wireless GSM/GPRS AT Commands (Document Number S000293I)

107

Chapter 13 – Specific AT

Commands

Cell Environment Description +CCED

Description:

This command can be used by the application to retrieve the parameters of the main cell and of up to
six neighboring cells.

There are two possible methods for the external application to determine these cell parameters:

On request by the application

Automatically by the product every 5 seconds.

Automatic mode is not supported during registration.

Values:

0 One shot requested
1 Automatic shots requested
2 Stop automatic shots

1 Main Cell:

If the Cell Identity is available

MCC, MNC, LAC, CI, BSIC, BCCH Freq (absolute), RxLev, RxLev Full, RxLev Sub, RxQual,
RxQual Full, RxQual Sub,Idle TS

If the Cell Identity is not available

MCC, MNC, LAC, BSIC, BCCH Freq (absolute), RxLev, RxLev Full, RxLev Sub, RxQual,
RxQual Full, RxQual Sub,Idle TS

2 Neighbor1 to Neighbor6:

If the Cell Identity is available

MCC, MNC, LAC, CI, BSIC, BCCH Freq (absolute), RxLev

If the Cell Identity is not available

MCC, MNC, LAC,, BSIC, BCCH Freq (absolute), RxLev

4 Main Cell Timing Advance

8 Main cell RSSI indications (RxLev) in a range from 0 to 31

16 =1 + =2 + =4 + Neighbor1 to

Neighbor6 Timing Advance (only available for mode=0) Neighbor1 to Neighbor6 Timing
Advance are only available in Idle Mode.

Indicates the step required for RSSI indications between 2 + CSQ unsolicited response.
The range of this step is [1,5]. Default value: 1. If this field is not indicated, the previous value is used.

Notes:

The response for the requested dump 1, 2, and 4 will be:

+CCED:, … ,
OK

Where is the ASCII string of the values (in decimal form except the LAC and CI values
which are in hexadecimal form) of the parameters. If a field cannot be measured – or is
meaningless – the parameter is not filled in and two consecutive commas are sent.

The response for the requested dump 8 will be a +CSQ response and not a +CCED. The 7.07
format for +CSQ is respected. The is not evaluated by this command, so the value
will always be 99.

+CSQ:, 99
OK

When automatic shots are selected, this +CSQ response is sent every time the measured
by the product is equal or greater than the value . So the level between 2
successive +CSQ responses is equal or greater than . Automatic shots are supported
in idle mode and during communication. The activation or deactivation of this flow (8) does not
affect the other flows.