Chapter 14 – SIM Toolkit

Multi-Tech Systems, Inc. Wireless GSM/GPRS AT Commands (Document Number S000293I)

146

Unsolicited Result: SIM Toolkit Control Response
+STCR

Description:

When the customer application makes an outgoing call or an outgoing SMS and if the call control facility
is activated, CALL CONTROL and SMS CONTROL responses can be identified. This is also applicable
to SS calls.

Values:

0

Control response not allowed.

1

Control response with modification.

Called number, Service Center Address or SS String in ASCII format.

MO destination address in ASCII format.

Text information in ASCII format.

Syntax: Command

Syntax:

+STCR: [,,,]

SIM Toolkit Give Response +STGR

Description:

This command allows the application/user to select an item in the main menu or to answer the following
proactive commands:

• GET INKEY

Key Pressed By The User.

• GET INPUT

Message Entered By The User.

• SELECT ITEM

Selected Item.

• SETUP CALL

User Confirmation.

• DISPLAY TEXT

User Confirmation To Clear The Message.

• SETUP EVENT LIST

Reporting events.

It is also possible to terminate the current proactive command session by sending a Terminal Response
to the SIM, with the following parameters:
• BACKWARD MOVE

Process a backward move

• BEYOND CAPABILITIES Command beyond ME capabilities

• UNABLE TO PROCESS ME is currently unable to process command

• NO RESPONSE

No response from the user

• END SESSION

User abort.


Values:

The values are listed after the Command Syntax Table.

Syntax:

Command syntax: +STGR=[,,]

Command

Possible responses

AT+STGR=[,,

OK
+CME ERROR:

For GetInput with =1:
AT+STGR=3,1

OK
+CME ERROR:

For GetInkey with =1
AT+STGR=2,1,”

OK
+CME ERROR:

AT+STGR=? OK

Values:

0

Item selection in the main menu.

1

User confirmation to clear a

‘Disp Text’.

2

Response for a

‘Get Inkey’.

3

Response for a

‘Get Input’.

4

Response for a

‘Setup call’.

6

Response for a

‘Sel Item’.

11 Reponse for a ‘Setup event list’.
95 Backward

move

96 Command beyond ME capabilities
97 ME currently unable to process command
98 No response from the user.
99 User

abort.