beautypg.com

Dte-dce character framing +icf – Multi-Tech Systems MMCModem GPRS (MTMMC-G) User Manual

Page 100

background image

Chapter 12 – V.24 and V.25 Commands

Multi-Tech Systems, Inc. Wireless GSM/GPRS AT Commands (Document Number S000293I)

100

DTE-DCE Character Framing +ICF

Description:

This command determines the local serial port start-stop (asynchronous) character framing that the
DCE uses.

Values:

0

Autodetect (not supported)

1

8 Data 2 Stop (supported)

parameter is ignored

2

8 Data 1 Parity 1 Stop (supported)

If no

provided, 3 is used by default as value

3

8 Data 1 Stop (supported)

parameter is ignored

4

7 Data 2 Stop (supported)

parameter is ignored

5

7 Data 1 Parity 1 Stop (supported)

If no

provided, 3 is used by default as value

6

7 Data 1 Stop (supported)

parameter is ignored

0

Odd

(supported)

1

Even

(supported)

2

Mark

(supported)

3

Space

(supported)

4

None

(supported)

Note:

All character framing formats settings of the serial interface (i.e., 801, 8E1, 8S1, 8N1, 7N1, 7O1,

7E1, 7S1 and 7N2) are supported on autobauding operation.

Syntax: Command

syntax: AT+ICF= [, ]

Command

Possible responses

AT+ICF?

+ICF: 3,4
OK
Note: Current values

AT+ICF=?

+ICF: (1-6),(0-4)
OK
Note: Possible values

AT+ICF=2,0

OK
Note: New values