Chapter 12 – V.24 and V.25 Commands
Multi-Tech Systems, Inc. Wireless GSM/GPRS AT Commands (Document Number S000293I)
100
DTE-DCE Character Framing +ICF
Description:
This command determines the local serial port start-stop (asynchronous) character framing that the
DCE uses.
Values:
0
Autodetect (not supported)
1
8 Data 2 Stop (supported)
2
8 Data 1 Parity 1 Stop (supported)
If no
3
8 Data 1 Stop (supported)
4
7 Data 2 Stop (supported)
5
7 Data 1 Parity 1 Stop (supported)
If no
6
7 Data 1 Stop (supported)
0
Odd
(supported)
1
Even
(supported)
2
Mark
(supported)
3
Space
(supported)
4
None
(supported)
Note:
All character framing formats settings of the serial interface (i.e., 801, 8E1, 8S1, 8N1, 7N1, 7O1,
7E1, 7S1 and 7N2) are supported on autobauding operation.
Syntax: Command
syntax: AT+ICF=
Command
Possible responses
AT+ICF?
+ICF: 3,4
OK
Note: Current values
AT+ICF=?
+ICF: (1-6),(0-4)
OK
Note: Possible values
AT+ICF=2,0
OK
Note: New values