Chapter 12 – V.24 and V.25 Commands

Multi-Tech Systems, Inc. Wireless GSM/GPRS AT Commands (Document Number S000293I)

101

DTE-DCE Local Flow Control +IFC

Description:

This command is controls the operation of local flow control between the DTE and DCE.

Values:

< DCE_by_DTE >

0 none

(supported)

1 Xon/Xoff local circuit 103

(not supported)

2 RTS

(supported)

3 Xon/Xoff global on circuit 103

(not supported)

Important Note:

When this parameter is set to 2 (DTE invokes flow control through RTS) DCE

behaviour is as follows:

If the DCE has never detected RTS in the high (or ON) condition since startup then it ignores

RTS as it assumes that this signal is not connected.

As soon as the DCE detects RTS high the signal acts on it. Therefore subsequent RTS

transition to OFF will prevent the DCE from sending any further data in both online and
offline modes.

This behavior allows the user to use the default settings (hardware flow control) and leave
RTS disconnected. In the case where RTS is connected and is high at least once, it acts on
the DCE.

< DTE_by_DCE >

0 none

(supported)

1 Xon/Xoff circuit 104

(not supported)

2 CTS

(supported)

Note

: When this parameter is set to 0 (none), then CTS is kept high all the time.

Syntax: Command

syntax:

AT+IFC=,

Command

Possible responses

AT+IFC?

+IFC: 2,2
OK
Note: Current values

AT+IFC=?

+IFC: (0,2),(0,2)
OK
Note: Possible values

AT+IFC=0,0 OK

Note: New values

Set DCD Signal &C

Description:

This commands controls the Data Carrier Detect (DCD) signal

.

Values:

0

DCD always on

1

DCD matches the state of the remote modem’s data carrier

Syntax: Command

syntax: AT&C

Command

Possible responses

AT&C0
Note: DCD always on

OK
Note: Command valid

AT&C1
Note: DCD matches state of the remote
modem’s data carrier

OK
Note: Command valid