Signal Quality +CSQ

Description:

This command determines the received signal strength indication () and the channel bit error rate
() with or without a SIM card inserted.

Values: :
0

-113 dBm or less

1

-111 dBm

2 to 30 -109 to –53 dBm

31

-51dBm or greater

99

not known or not detectable

:

0…7:

as RXQUAL values in the table GSM 05.08

99

not known or not detectable

Syntax:

AT+CSQ

Command Possible responses
AT+CSQ

+CSQ: ,
OK
(Note: and as defined below)



Operator Selection +COPS

Description:

There are three possible ways of selecting a Public Land Mobile Network (PLMN) operator:

The product is in

manual mode. It then tries to find the operator specified by the application

and if found, tries to register.

The product is in

automatic mode. It then tries to find the home operator and if found, tries to

register. If not found, the product automatically searches for another network.

The product enters into

manual/automatic mode, and then tries to find an operator as

specified by the application (as in manual mode). If this attempt fails, it enters

automatic

mode. If this is successful, the operator specified by the application is selected. The mobile
equipment then enters into

automatic mode.

Note:

The read command returns the current mode and the currently selected operator. In manual

mode, this PLMN may not be the one set by the application (as it is in the search phase).

These commands are not allowed during communication.

Values:

0

automatic (

default value)

1

manual

2

deregistration; ME will be unregistered until =0 or 1 is selected.

3

set only (for read command AT+COPS?)

4

manual / automatic ( shall be present), if manual selection fails, automatic mode is
entered.

: format of field

0

long alphanumeric format

1

short alphanumeric format

2

numeric (default value)

Status of operator

0

unknown

1

available

2

current

3

forbidden