beautypg.com

Hang-up +wath – Multi-Tech Systems MMCModem GPRS (MTMMC-G) User Manual

Page 136

background image

Chapter 13 – Specific AT Commands

Multi-Tech Systems, Inc. Wireless GSM/GPRS AT Commands (Document Number S000293I)

136

Hang-up +WATH

Description:

This command disconnects the remote user, specifying a release cause and the location. In the case of
multiple calls, all calls are released (active, on-hold and waiting calls).

Values: :

decimal value from 1 to 127
See table “Failure Cause from GSM 04.08 recommendation.”

:

optional parameter (default value =0)
values as defined in 04.08
0

user

1

private network serving the local user

2

public network serving the local user

3

transit network

4

public network serving the remote user

5

private network serving the remote user

7

international network

10

network beyond interworking point

Note:

In order to have a “Normal Release”, use the ATH command.

Syntax:

Command Syntax: AT+WATH=,

Command

Possible responses

AT+WATH=31
Note: Ask for disconnection with release
cause=normal and location=USER

OK
Note: All calls, if any, are released

AT+WATH=? +WATH:

(1-127),(0-5,7,10)

AT+WATH=17,2
Note: Ask for disconnection with release
cause=user busy and location= public network
serving the local user

OK
Note: All calls, if any, are released