Misc(1) tab – Motorola ENTERPRISE DIGITAL ASSISTANT MC70 User Manual
Page 87
Application Deployment for Mobile 5.0 4 - 21
Misc(1) Tab
Use this tab to configure various miscellaneous features.
Figure 4-10
Misc(1) Tab
Table 4-8
Misc(1) Tab
Field
Description
Auto-load
Use this drop-down list to specify how to invoke the AirBEAM Smart Client when the
client device is rebooted. Options are:
Disable: the AirBEAM Smart Client is not invoked automatically during the boot
sequence.
Interactive: the AirBEAM Smart Client is invoked during the boot sequence and
begins package synchronization. The Synchronization Dialog box appears and you
must tap OK when the process completes.
Non-interactive: the AirBEAM Smart Client is invoked during the boot sequence and
begins package synchronization. The Synchronization Dialog box appears, but you
don’t have to tap OK when the process completes. The Synchronization Dialog box
closes automatically.
Background: the AirBEAM Smart Client is invoked automatically during the boot
sequence. The package synchronization process starts automatically. Nothing is
displayed while the synchronization process is occurring.
RAM Management
This check box specifies whether the automatic RAM management is enabled during
package synchronization.
Enable this to invoke RAM management logic when there is not enough free disk
space to download a package. The RAM management logic attempts to remove any
discardable AirBEAM packages resident on the client.
Suppress Separator
This check box specifies whether to suppress the automatic insertion of a file path
separator character when the client generated server package definition file names.
When enabled, the parameter also disables appending .apd to the package. This
feature is useful for AS/400 systems, in which the file path separator character is a
period. Enabling this feature appends the server directory (Directory) and package
name (Package 1, Package 2, Package 3, and Package 4) “as is” when building the
name for the server package definition file.
When this feature is disabled, a standard file path separator is used to separate the
server directory (Directory) and package name (Package 1, Package 2, Package 3,
and Package 4) when building the name for the server package definition file. In
addition, an .apd extension is appended automatically.
TFTP
This check box specifies whether to use the TFTP protocol to download files. By
default, the AirBEAM Smart Client uses the FTP protocol.
WNMS
This check box specifies whether the AirBEAM Smart Client uploads a WNMS
information file at the end of each version synchronization.