Page 161
Wireless Applications 7 - 37
2.
Enter a filename in the
Name:
field. The default filename is WCS_PROFILES.REG.
3.
In the
Folder:
drop-down list, select the desired folder.
4.
Tap
Save
.
Selecting
Export All Profiles
saves the current profile. This information is used to determine which profile to
connect with after a warm boot or cold boot.
Cold Boot Persistence
Export options and profiles to provide cold boot persistence. Save the exported registry files in the Application
folder to use them on a cold boot and restore previous profile and option settings.
Currently, only server certificates can be saved for cold boot persistence. To save server certificates for cold
boot persistence, save the certificate files in the folder Application to install the certificates automatically on a
cold boot.
Registry Settings
Use a registry key to modify some of the parameters. The registry path is:
HKLM\SOFTWARE\Symbol Technologies, Inc.\Configuration Editor
Log On/Off Application
When the user launches the Log On/Off application, the EDA may be in two states; the user may be logged
onto the EDA by already entering credentials through the login box, or there are no user logged on. Each of
these states have a separate set of use cases and a different look to the dialog box.
NOTE
User certificates cannot be saved for cold boot persistence at this time.
Table 7-27
Registry Parameter Settings
Key
Type
Default
Description
CertificateDirectory
REG_SZ
\\Application
The default directory to find certificates.
EncryptionMask
REG_DWORD
0x0000001F
Defines the supported encryption types. This is a
bitwise mask with each bit corresponding to an
encryption type.
1 = Type is supported
0 = Type is not supported
Bit Number
Encryption Type
0
None
1
40-Bit WEP
2
128-Bit WEP
3
TKIP
4
AES (Fusion 2.5 only)