6 bidin instruction, Melsec-q, 9 dedicated instructions 9.6 bidin instruction – MITSUBISHI ELECTRIC QJ71C24N User Manual
Page 244: Set data, Control data, Point
9 - 14 9 - 14
MELSEC-Q
9 DEDICATED INSTRUCTIONS
9.6 BIDIN Instruction
This instruction receives data using the bidirectional protocol.
Applicable device
Internal device
(System, user)
MELSECNET/H,
MELSECNET/10
Direct J \
Set
data
Bit
Word
File register
Bit
Word
Special module
U \G
Index register Zn
Constant Others
(S)
—
—
(D1)
—
—
(D2)
—
GP.BIDIN
BIDIN
BIDIN
(D2)
(S)
(D1)
(D2)
(D1)
(S)
G.BIDIN
Un
Un
Command
Command
[Executing
condition]
[Instruction
code]
Set data
Description
Set by
Data type
Un
Start I/O signal of the module
(00 to FE: Top two-digit when I/O signals are expressed in 3-digit.)
User
BIN16 bit
(S)
Head number of the devices in which control data is stored.
User,
system
(D1)
Head number of the devices in which receive data is stored.
System
Device name
Set data
(D2)
Bit device number to be turned on at completion of execution.
System
Bit
The file register per local device and program cannot be used as the set data.
Control data
Device
Item
Set data
Setting range
Set by
2
(S) + 0
Receive channel
• Set receive channel
1: Channel 1 (CH1 side)
2: Channel 2 (CH2 side)
1, 2
User
(S) + 1
Reception result
• Reception result by a BIDIN instruction are
stored.
0: Normal
—
System
(S) + 2
Receive data count
• The number of data received is stored.
1
1 or more
System
(S) + 3
Allowable number of
receive data
• Set the allowable number of words for received
data that can be stored in (D1).
1 or more
User
POINT
(1) The command of G (P).BIDIN cannot be converted into pulse.
(2) G (P).BIDIN should be executed while the read request of the input/output
signal is turned on.