6 - 10 6 - 10

MELSEC-Q

6 DATA COMMUNICATION USING THE NON PROCEDURE PROTOCOL

2) Reception by received data count

When the received data count is set larger than the receive data storage

area, the receive buffer memory length (default: 512 words) -1 set in buffer

memory addresses A7

H

/147

H

is processed as the received data count.

(Receive data storage area) > (Data length received from external device)

(Example) When 550 words of data is received through the CH1 interface

in three parts when the CH1 interface receive area consists of

addresses 600

H

to 7FF

H

(default value)

External device

Reception data read
request signal

X3

511 words

Sequence program

INPUT

INPUT

39 words

INPUT

472 words

78 words

433 words

117 words

1st data

2nd data

3rd data

Read data....
1st 511 words

Read data....
1st 39 words and
2nd 472 words

Q series C24