MITSUBISHI ELECTRIC GOT1000 GT15-J71E71-100-U User Manual
User's manual, Gt15 ethernet communication unit, Overview
User's Manual
GT15-J71E71-100
Thank you for purchasing the GOT1000 Series.
GT15 Ethernet communication unit
Prior to use, please read both this manual and detailed
manual thoroughly to fully understand the product.
MODEL
GT15-J71E71-100-U
MODEL
CODE
1D7M29
IB(NA)-0800314-C(0507)MEE
zSAFETY PRECAUTIONSz
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this prod-
uct.
In this manual, the safety precautions are ranked as "DANGER" and
"CAUTION".
Note that the
CAUTION level may lead to a serious accident
according to the circumstances.
Always follow the precautions of both levels because they are impor-
tant to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury
or physical damage.
DANGER
CAUTION
[DESIGN PRECAUTIONS]
[INSTALLATION PRECAUTIONS]
[WIRING PRECAUTIONS]
[STARTUP AND MAINTENANCE PRECAUTIONS]
z Do not bunch the control wires or communication cables with
the main circuit or power wires, or lay them close to each other.
As a guide, separate the lines by a distance of at least 100 mm
(3.94 inch) otherwise malfunctions may occur due to noise.
z Be sure to shut off all phases of the external power supply used
by the system before mounting or removing this unit to/from the
GOT.
Not doing so can cause a unit failure or malfunction.
z Before connecting the Bus connection cable to this unit, always
shut off GOT power and PLC CPU power externally in all
phases.Not doing so can cause a malfunction.
z Use this unit in the environment given in the general
specifications of the GT15 User's Manual.Not doing so can
cause an electric shock, fire, malfunction or product damage or
deterioration.
z When installing this unit to the GOT, fit it to the connection
interface of the GOT and tighten the mounting screws in the
specified torque range.
Undertightening can cause a drop, failure or malfunction.
Overtightening can cause a drop, failure or malfunction due to
screw or unit damage.
z Be sure to shut off all phases of the external power supply used
by the system before wiring.
Failure to do so may result in an electric shock, product damage
or malfunctions.
z Use crimp-contact, pressure-displacement or soldering to wire
the connectors for external connections properly using the
manufacturer-specified tools.
If the connection is incomplete, it may cause the module to short
circuit, catch fire, or malfunction.
z Connect the connectors to the unit securely.
z Always secure the cables connected to the unit, e.g. run them in
conduits or clamp them.
Not doing so can cause unit or cable damage due to dangling,
moved or accidentally pulled cables or can cause a malfunction
due to a cable contact fault.
z Before starting cleaning, always shut off GOT power externally
in all phases. Not doing so can cause a unit failure or
malfunction.
DANGER
DANGER
CAUTION
DANGER
CAUTION
DANGER
[DISPOSAL PRECAUTIONS]
[TRANSPORTATION PRECAUTIONS]
Manuals
The following shows manuals relevant to this product.
For relevant manuals, refer to the PDF manual stored within the
drawing software used.
© 2005 MITSUBISHI ELECTRIC CORPORATION
Compliance with the EMC and Low Voltage
Directives
When incorporating the Mitsubishi GOT into other machinery or
equipment and keeping compliance with the EMC and low voltage
directives, refer to Chapter 4, "EMC Directives and Low Voltage
Directives" of the manual (GT15 General Description) included
with the GOT used.
The CE logo is printed on the rating plate of the GOT, indicating
compliance with the EMC and low voltage directives.
By making this product conform to the EMC directive and low
voltage instruction,it is not necessary to make those steps
individually.
z Do not disassemble or modify any unit.
This will cause failure, malfunction, injuries, or fire.
z Do not touch the conductive areas and electronic parts of this
unit directly.
Doing so can cause a unit malfunction or failure.
z Exercise care to avoid foreign matter such as chips and wire
offcuts entering the unit.
Not doing so can cause a fire, failure or malfunction.
z Do not hold the cable part when unplugging any cable
connected to the unit. Doing so can cause unit or cable damage
or a malfunction due to a cable contact fault.
z Always make sure to touch the grounded metal to discharge the
electricity charged in the body, etc., before touching the unit.
Failure to do so may cause a failure or malfunctions of the unit.
z Dispose of this product as industrial waste.
z Make sure to transport the GOT main unit and/or relevant unit(s)
in the manner they will not be exposed to the impact exceeding
the impact resistance described in the general specifications of
the GT15 User's Manual, as they are precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
Detailed Manual
Manual name
Manual Number
(Type code)
GT15 User's Manual
(Option)
SH-080528ENG
(1D7M23)
GOT1000 Series Connection Manual
(Option)
SH-080532ENG
(1D7M26)
Relevant Manuals
CAUTION
CAUTION
CAUTION
1. Overview
This User's Manual describes the GT15 Ethernet
communication unit.
The GT15-J71E71-100 is required when performing Ethernet
connection or Gateway function with GOT.
After unpacking the box of GT15-J71E71-100, please check if
the following items are contained.
2. Specifications
2.1 Performance Specifications
The performance specifications of the Ethernet communication
unit are indicated below.
Refer to the used GT15 User's Manual for the general
specifications of the Ethernet communication unit.
*1 This depends on the specifications of the Ethernet network sys-
tem to which the GOT is connected.
For the details, refer to the manual of Ethernet module of con-
nected PLC.
*2 If multiple network equipments (including GOT) are connected
within a segment, the network load would increase.
In such condition, the communication performance between GOT
and PLC may be declined.
The decline of the communication performance may be improved
by the following measures.
• Using switching hubs.
• Reducing the number of monitoring devices of the GOT.
Product name
Model name
Quantity
Ethernet communication unit
GT15-J71E71-100
1
Mounting screw set (2 pieces
of screw,2 pieces of label)
-
1
For information concerning necessary OS in case of using GT15-
J71E71-100,refer to GOT 1000 Series Connection Manual.
Item
Specification
Transmission
specifications
Data transfer method 10BASE-T
100BASE-TX
Transmission
method
Base band
Base band
Maximum node to
mode distance
200m
200m
Maximum segment
length
100m
100m
Maximum number of
cascade connection
4 steps
2 steps
Number of units mounted to GOT
Only 1 unit can be mounted
to the extension unit
interface.
Connecting
condition
Number of GOTs
connected
128 (Recommend 16 or
less)*1*2
GOT placing
distance
100m*1
Internal current consumption(DC5V)
0.22A
Weight
0.09kg
2.2 Specifications of the related devices
Use the connection cable and the hub which meet the
IEEE802.3 10BASE-T/100BASE-TX standard.
3. Name of the Parts
Item
Specifications
10BASE-T
100BASE-TX
Cable
Non-shielded twisted pair
wire (UTP cable)
(category3(4, 5))
Shielded twisted pair wire
(STP cable)
(category5)
Connector
RJ45jack
RJ45jack
Hub
10Mbps hub
100Mbps hub
No.
Name
Description
1)
Mounting screw
Mounting screws fixed with the
front communication unit or GOT.
2)
Interface connector
Connector connected to the front
communication unit or GOT.
3)
Extension connector
Connector with which the back
communication unit is fixed.
4)
Ethernet connector
Connector to which Ethernet
cable is connected.
5)
100M LED
It lights up during 100 Mbps
transmission.
6)
SD/RD LED
It blinks during data sending/
receiving.
7)
Rating plate
-
1)
7)
3)
2)
6)
4)
5)
4. Installation Procedure
(1) Power off the GOT.
(2) Remove the one extension unit covers of the GOT.
(3) Fit the Ethernet communication unit along the groove
of the GOT case.
(4) Fasten the Ethernet communication unit by tightening
its mounting screws (2 places) with tightening torque
0.36 to 0.48 N•m.
(5) When mounting an Ethernet communication unit on
the outer layer, remove the connector cover and the
seal.
When not mounting any communication unit on the
outer layer, stick accessory labels on the top of
mounting screws (2 places) to cover the top of them
in order to avoid receiving electrostatic.
Keep the connector cover fixed.
Keep the seal stuck as it is.
Seal
Accessory labels
Connector cover
5. External Dimensions
Dimensions of X when mounted to the GOT.
Unit: mm (inch)
Point
(1) Grounding work for the 10BASE-T and 100BASE-TX requires
appropriate safety measures.
Consult professionals for work details including terminal of
connection cables and other plant work such as laying of main
cables.
(2) If you remove the Ethernet unit, detach it from specified
direction (shown PULL) so as not to break a connector.
8.4”
23 (0.91)
10.4”, 12.1”, 15”
21 (0.83)
Ethernet is a registered trademark of Xerox Corporation, U.S.
Other business or product names mentioned herein are a
trademark or registered trademark of each company.
2.5
(0.10)
21
(0.83)
3 (0.12)
63 (2.48)
GOT main unit
0.5
(0.02)
98 (3.89)
1
12 (4.41)
0.4
7
(0.28)
(0.31)
8
30.5 (1.2)
21.5 (0.85)
X
(0.02)
Warranty
Mitsubishi will not be held liable for damage caused by factors found
not to be the cause of Mitsubishi; machine damage or lost profits
caused by faults in the Mitsubishi products; damage, secondary
damage, accident compensation caused by special factors
unpredictable by Mitsubishi; damages to products other than
Mitsubishi products; and to other duties.
For safe use
• This product has been manufactured as a general-purpose part for
general industries, and has not been designed or manufactured to
be incorporated in a device or system used in purposes related to
human life.
• Before using the product for special purposes such as nuclear
power, electric power, aerospace, medicine or passenger
movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control.
However, when installing the product where major accidents or
losses could occur if the product fails, install appropriate backup or
failsafe functions in the system.
Country/Region Sales office/Tel
U.S.A
Mitsubishi Electric Automation Inc.
500 Corporate Woods Parkway Vernon Hills, IL 60061
Tel : +1-847-478-2100
Brazil
MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.
Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar
Paraiso, Sao Paulo, SP Brazil
Tel : +55-11-5908-8331
Germany
Mitsubishi Electric Europe B.V. German Branch
Gothaer Strasse 8 D-40880 Ratingen, GERMANY
Tel : +49-2102-486-0
U.K
Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, Hatfield, Herts., AL10 8XB,UK
Tel : +44-1707-276100
Italy
Mitsubishi Electric Europe B.V. Italian Branch
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, 20041 Agrate B., Milano, Italy
Tel : +39-039-6053344
Spain
Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi 76-80
08190 - Sant Cugat del Valles, Barcelona, Spain
Tel : +34-93-565-3131
France
Mitsubishi Electric Europe B.V. French Branch
25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France
TEL: +33-1-5568-5568
South Africa
Circuit Breaker Industries LTD.
Tripswitch Drive, Elandsfontein Gauteng, South Africa
Tel : +27-11-928-2000
Hong Kong
Ryoden Automation Ltd.
10th Floor, Manulife Tower, 169 Electric
Road, North Point, HongKong
Tel : +852-2887-8870
China
Ryoden Automation Shanghai Ltd.
3F Block5 Building Automation
Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China
Tel : +86-21-6120-0808
Taiwan
Setsuyo Enterprise Co., Ltd.
6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang,
Taipei Hsine, Taiwan
Tel : +886-2-2299-2499
Korea
HAN NEUNG TECHNO CO.,LTD.
1F Dong Seo Game Channel Bldg.,660-11, Deungchon-dong
Kangsec-ku, Seoul, Korea
Tel : +82-2-3660-9552
Singapore
Mitsubishi Electric Asia Pte, Ltd.
307 Alexandra Road #05-01/02,
Mitsubishi Electric Building Singapore 159943
Tel : +65-6473-2308
Thailand
F. A. Tech Co.,Ltd.
898/28,29,30 S.V.City Building,Office Tower 2, Floor 17-18 Rama 3
Road, Bangkpongpang, Yannawa, Bangkok 10120
Tel : +66-2-682-6522
Indonesia
P.T. Autoteknindo SUMBER MAKMUR
Jl. Muara Karang Selatan Block a Utara No.1 Kav. No.11 Kawasan
Industri/Pergudangan Jakarta - Utara 14440
Tel : +62-21-663-0833
India
Messung Systems Put,Ltd.
Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,
PUNE-411026, India
Tel : +91-20-712-2807
Australia
Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, PostalBag, No 2,
Rydalmere, N.S.W 2116, Australia
Tel : +61-2-9684-7777
HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212,JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry
of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan on recycled paper.