Changing the initial settings (setup mode) – Fostex D2424 User Manual
Page 105
105
Model D2424 Reference Manual (Changing the Initial Settings
Changing the Initial Settings (SETUP mode)
Execution item
Display
Refer page
Community
Editing a program title
Title Edit PGM** ?
37
-
Deleting a program
Delete PGM** ?
36
-
Loading song data
Load PGM ?
84
-
Saving song data
Save PGM ?
84
-
Optimizing a Disk
Disk Optimize ?
30
-
Formatting a Disk
Disk Format ?
30
-
Check item
Display
Refer page
Community
Check of the Event number on the track
NOs Of Event ?
122
-
Check of the current drive status
Drive Info ?
127
-
Parameters
Display
Default setting
Refer page
Community
Setting a time signature
Signature Set ?
001bar 4/4
107
Setting a Tempo
Tempo Map Set ?
001bar 1 120
109
Setting the metronome function
Click ?
Off
111
Setting a preroll time
Preroll Time ?
00s
112
Setting MIDI sync output signal
Midi Sync Out ?
MTC
113
Setting an MTC frame rate
Frame Rate ?
25 frame
113
Setting an MTC offset value
MTC OFFSET
00h 59m 57s 00f 00sf
114
Setting Offset mode
Offset Mode ?
ABS
115
Setting a reference time code
Ref. TC ? Void!
Available with option Model 8345 (Refer to APPENDIX)
Setting the slave type
Slave Type ?
Vari
116
Setting the record protect function
Rec Protect ?
Off
116
Setting digital input tracks
D. in?
Analog
117
Setting digital output tracks
D. out ?
adat
118
Setting BAR/BEAT resolution mode
Resolution ?
Off
119
Setting the MIDI device ID number
Device ID ?
00
120
Setting the operating clock
Clock Sel ?
Int.
121
Setting the SYNC preset
Sync Preset ?
Available with option Model 8345 (Refer to the APPENDIX)
Setting the Virtual LTC display
Virtual LTC ?
Available with option Model 8345 (Refer to the APPENDIX)
Setting the chase offset display
Offset Disp ?
Available with option Model 8345 (Refer to the APPENDIX)
Setting the internal clock
Date & Time Set ?
Please refer to the “Quick Operation Guide.”
Setting the Auto EE mode
Auto EE Mode ?
Off
123
Setting the Foot switch function
Foot SW ?
Punch IO
123
Setting the stop function at the mark point
Mark Stop MD ?
Off
124
Setting the reference level
Ref. Level ?
-12dB
125
Setting input/output Balance/Unbalance
BAL/UNBAL ?
UNBAL
126
Setting the drive
Drive Sel. ?
IDE
129
-
Setting the display contrast level
Contrast ?
Level 6
130
: Modes applicable program by program. They can be saved/loaded.
: Modes applicable to all programs. They cannot be saved/loaded.
The SETUP mode offers the Changing the initial settings menus to configure the operating environment
of the recorder, a “Check” menu that enables you to check the number of events of each track and the
“Execution” menus to execute certain operations such as save/load and disk formatting.
In this chapter we will explain procedures only on
setting the internal clock) and
the “Quick operation guide,” and on the “Execution” menu, the “Reference page” written in