Operator’s manual, Reload application rates – Great Plains DICKEY-john AI100 10-inch Virtual Terminal User Manual
Page 60
OPERATOR’S MANUAL
10" Virtual Terminal
11001-1440-200701
58 / TASK CONTROLLER
VIEW INTELLIAG DATA WHILE RUNNING A TASK
While a task is running, a user can return to the IntelliAg Main Work screen
to monitor normal operating conditions. A task icon displays on the IntelliAg
Main Work screen indicating that a task is running and the target rate
symbol indicates that the application at which at the task controller is
communicating.
To stop a task, return to Task Controller.
Figure 53
IntelliAg Work Screen
RELOAD APPLICATION RATES
Reload resets a system that has been running a task under VRT Application
map control. An SD Card graphic icon on the IntelliAg Work screen
indicates this condition. The Reload button appears on the IntelliAg Work
screen to select current rates or to reload IntelliAg rates.
The Reload button only appears if a task is stopped in Task Controller and:
– ground speed is greater than 0
– the master switch in ON
– the implement lift switch is down (operate mode)
An alarm will occur within a 5-second period:
– Press the Current button to continue to run a task under VRT
Application map control
– Press the Reload button to reset the system to IntelliAg rates
Task
Running
RELOAD
TC
Task Controller
Target Rate
Task Controller button
Reload button
IntelliAg button