OPERATOR’S MANUAL
10" Virtual Terminal
11001-1440-200701
TRACTOR ECU / 27
PTO CONFIGURATION
The PTO Configuration screen determines:
• PTO Working Speed
• PTO High Speed Alarm
• PTO Low Speed Alarm
To configure the PTO:
1. Enter the PPR (pulses per revolution) or number of teeth on the sensor
gear in the PPR input box.
PTO SETUP
1. Enter the value at which the PTO is considered operating in Work
mode.
2. Enter high and low speed alarm limits. If the PTO speed exceeds the
specified maximum, a full alarm screen will display. If the PTO speed is
below the specified minimum, an audio indicator will sound and the
PTO low speed will display on the TECU Work screen.
NOTE: Any values set at 0 will disable
alarms.
Figure 20
PTO Configuration Screen
All necessary precautions must be taken to ensure user safety
around moving parts. Failure to practice all necessary caution may
result in serious injury or death. Refer to the manufacturer’s
operator manual for safety warnings when operating a PTO.
Pulses
Per
Revolution
PTO Configuration button