Operator’s manual, Tecu setup, Work mode – Great Plains DICKEY-john AI100 10-inch Virtual Terminal User Manual
Page 25
OPERATOR’S MANUAL
10" Virtual Terminal
11001-1440-200701
TRACTOR ECU / 23
TECU SETUP
The Tractor ECU (TECU) Setup screen allows selection of the control
functions to be monitored and entry of implement width, if desired.
1. Press the TECU Setup button to display the Setup screen.
2. Select the desired sensors to activate “In Work” status on the TECU
Work screen by pressing the desired input box.
NOTE: Implement width on the Tractor
ECU setup screen is
independent from the IntelliAg
or other connected applications
and is only used for area
accumulation.
Figure 17
TECU Setup Screen
WORK MODE
When all parameters have been configured and setup, the TECU Work
screen will display all enabled functions.
To start accumulating data and activate alarms, the system must meet ALL
criteria that is configured in the system to begin operating in the Work
mode.
Work status is identified on the TECU Work screen by the work indicator
icon (green = In Work) refer to (
Figure 15
).
Implement
Width
In Work
Settings
TECU Setup button