Operator’s manual – Great Plains DICKEY-john AI100 10-inch Virtual Terminal User Manual
Page 28
OPERATOR’S MANUAL
10" Virtual Terminal
11001-1440-200701
26 / TRACTOR ECU
6. The value in yellow is the current calibration value that does not
change when the stop button is pressed.
7. To accept the last-run value, the Save button will transfer the last-run
value into the current calibration position in yellow and save.
8. To enter an averaged calibration, highlight the calibration number at
the current calibration position and manually enter the new value.
9. Once the correct data has been entered, it is automatically saved.
MAXIMUM AND MINIMUM GROUND SPEED LIMITS
Maximum and Minimum alarms can be set at a user-defined speed that will
activate an audible alarm anytime speed has met the maximum or minimum
ground speed conditions. Setting to 0.0 will disable the alarms.
WHEEL SLIP LIMITS
A %-based, wheel slip alarm can be set to indicate any wheel slippage. A
full alarm will display and must be acknowledged by pressing the ESC key
or the checkmark softkey.
Save button