2. I/O data and sequence control

2−28

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Assignment of the status bytes (parametrisation)

SCON
Byte 1

B7
OPM2

B6
OPM1

B5
FCT_MMI

B4
24VL

B3
FAULT

B2
WARN

B1
OPEN

B0
ENABLED

y

Operating mode
acknowledgement

Software
device
control

Load
voltage
applied

Fault

Warning

Operation
enabled

Drive
enabled

Subindex
Byte 2

Subindex of the transferred parameter

Param.
identifier
Bytes 3+4

Reply identifier and parameter number:
Bit

Content

Description

0...11

PNU

Parameter number of the parameter to be transferred

12 to 15 ResID

Reply identifier, see section 6.1.1

Param.
value
Bytes
5 to 8

Value of the parameter to be transferred
(32−bit number)