B. Basic controlling principles

B−30

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Effect

Cause

Remedy

Stability problem, higher−frequency swinging around the setpoint position

1

2

3

Ĉ Incorrect mass load confiĆ

gured or programmed

Ĉ Amplification gain set too

high

Ĉ Cushioning factor set too low
Ĉ Signal filter factor set too

high (smooth acceleration/
speed signal but continuous
swinging)

Ĉ or very noisy acceleration

signal with high amplitude

Ĉ Minimum mass load not

reached

Ĉ Too small tolerance

demanded

·

Correct the configuration

·

Correct the parameter

·

Correct the parameter

·

Reduce signal filter factor

·

Increase signal filter factor

·

Increase basic load

·

Increase tolerance

1

Setpoint position

2

Actual position

3

Speed