beautypg.com

10 parameters of the default values, Parameters of the default values, Section 5.4.1 – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 255

background image

5. Parameter

5−67

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

5.4.10 Parameters of the default values

Default value speed position mode

PNU

PNU: 600

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Speed (index = 6)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Dimension Default

Minimum

Maximum

SI 0,001 m/s

2.000

10

10.000

1

°/s

1.000

10

10.000

Imperial 0.01 ft/s

650

3

3.281

1

°/s

1.000

10

10.000

This value contains the speed preset by the user. It is used in all records with position control where
no individual speeds are specified.
RPC−Bit = Bit 0 (= 00000001h)

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Default value speed force mode

PNU

PNU: 601

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Speed (index = 6)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Force control is not permissible with semi−

d

SI 0,001 m/s

50

0

500

p

rotary drives.

Imperial 0.01 ft/s

15

0

164

This value contains the speed preset by the user. It is used in all records with force control where no
individual speeds are specified.
RPC−Bit = Bit 1 (= 0000.0002h)

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.