beautypg.com

Dimension reference system for pneumatic drives, B.2.1 – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 351

background image

B. Basic controlling principles

B−9

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

B.2

Dimension reference system for pneumatic drives

B.2.1

Dimension reference system with absolute measuring system

System of units for linear drives with absolute measuring system

1

CZ/AZ

a’

b

c

PZ

d

e

TP/AP

USE

LSE

2

Positions increasing in size, positive" travel, right−hand" travel

SZ

SZ

Sensor/measuring system zero point (sensor zero point)

a’

Offset axis zero point
(distance AZ − SZ so far

CZ

Cylinder zero point, stop

(distance AZ − SZ, so far
mounting offset")

AZ

Axis zero point

b

Offset project zero point

PZ

Project zero point

c

Offset target/actual position

LSE

Lower software end position

d, e

Offset software end posiĆ
tions:

USE

Upper software end position

1

Effective stroke

TP, AP

Target/actual position

2

Cylinder/axis length

Tab. B/7: Dimension reference system for pneumatic drives with absolute measuring system

The vectors a’ to e are user specifications provided these
cannot be recognised (e. g. cylinder and measuring system
length with the DGCI).

The axis zero point always has to be on the cylinder zero
point! This is necessary because the controller requires the
absolute piston position within the cylinder.