Dimension reference system for pneumatic drives, B.2.1 – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 351
B. Basic controlling principles
B−9
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
B.2
Dimension reference system for pneumatic drives
B.2.1
Dimension reference system with absolute measuring system
System of units for linear drives with absolute measuring system
1
CZ/AZ
a’
b
c
PZ
d
e
TP/AP
USE
LSE
2
Positions increasing in size, positive" travel, right−hand" travel
SZ
SZ
Sensor/measuring system zero point (sensor zero point)
a’
Offset axis zero point
(distance AZ − SZ so far
CZ
Cylinder zero point, stop
(distance AZ − SZ, so far
mounting offset")
AZ
Axis zero point
b
Offset project zero point
PZ
Project zero point
c
Offset target/actual position
LSE
Lower software end position
d, e
Offset software end posiĆ
tions:
USE
Upper software end position
1
Effective stroke
TP, AP
Target/actual position
2
Cylinder/axis length
Tab. B/7: Dimension reference system for pneumatic drives with absolute measuring system
The vectors a’ to e are user specifications provided these
cannot be recognised (e. g. cylinder and measuring system
length with the DGCI).
The axis zero point always has to be on the cylinder zero
point! This is necessary because the controller requires the
absolute piston position within the cylinder.