Installing a modular EDS file
You will require the following files for the CPX terminal:
File type
File name
Language
Description
EDS
cpx_chassis.eds
English
Base file for modular EDS.
EDS
cpx_fb11...eds
English
Provides the communication adapter in the conĆ
figuration program.
EDS
cpx_...eds
English
There is an EDS file for every module type. It
contains the information needed for configurĆ
ation and parametrisation.
ICO
cpx_...ico
ć
Icon file for representing the CPX terminal or
mode in the configuration program.
Tab. C/4: Configuration files (modular EDS) for the CPX terminal for DeviceNet
Installing modular EDS
files
·
Install the files with your configuration program.
You must install at least the Chassis EDS and the EDS files of
the required modules.
Recommendation: Install all EDS files.
Icon files
Depending on the configuration program used, you can asĆ
sign icon files (.ico format) to the CPX terminal or the CPX
modules. The CPX terminal or the modules will then be repreĆ
sented accordingly in the configuration program.
Notes on installing the EDS files and the icon files can be
found in the documentation for your configuration program.