Festo Контроллер позиционирования CPX-CMAX User Manual
Page 295
6. Parametrisation
6−5
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Error
Error description
Error
Error description
0
Impermissible PNU.
1
Parameter value cannot be changed.
2
Lower or upper value limit exceeded.
3
Invalid subindex.
11
No higher−order controller. FCT must accept device control in order to write this parameter.
This error can only be generated via the service interface.
12
The password entered is wrong.
17
Request cannot be carried out due to operating status. Please check operating mode, stop
and enable signals.
101
Request ID is not supported.
102
Parameter cannot be read (password).
103
The system of measurement has not been configured yet. Access to the parameter is not
possible.
104
The cylinder type has not been configured yet. Access to the parameter is not possible.
105
The system of measurement has already been configured and cannot be changed without a
data reset.
106
Cylinder type cannot be changed since it does not match the system of measurement.
107
The value cannot be changed since there is identification data. Please reset the identification
data before writing the value.
108
The parameter value does not match the hardware recognised.
(Note: the cylinder type must match the measuring system)
109
Serial numbers cannot be changed before the identification data has been reset.
Tab. 6/5: Error numbers for parameter transmission