4 configuration of diagnostic messages and faults, Configuration of diagnostic messages and faults, Diagnostic events filter – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 180
4. Faults and diagnostics
4−44
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
4.4
Configuration of diagnostic messages and faults
PNU 228 permits the configuration of diagnostic events.
PNU 228: Configuration of diagnostic events
Index
Description
Default
1
Diagnostic events filter
0x0000000F
2
Fault messages filter
0x0000007F
3
Configuration of fault messages
0x000000C0
Tab. 4/14: Configuration of the diagnostic messages
Diagnostic events filter
These settings allow you to determine which diagnostic evĆ
ents should be recorded. PNU 228:01 allows you to exclude
specific less important events from the diagnostic memory
records.
PNU 228:01: Diagnostic events filter
Which events other than faults do you want recording?
Bit
Description
SpecifiĆ
cation
0
Record warnings
1
1
Record configuration events (data reset, identification etc.)
1
2
Record reset commands
1
3
Record switch−on processes
1
4 ... 31
reserved (=: 0 !)
0
Tab. 4/15: Configuration of the diagnostic messages ć diagnostic events filter