5. Parameter
5−42
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Additional axis status
PNU
PNU: 308
Index: 1
Max index: 1
Class: Var
Data type: bitarray
Values
Default:
−
Write:
−
Additional status information of the controller.
These are also valid in parametrising mode if SPOS is not available.
Bit 0
Referenced
SPOS.REF
Bit 1
Motion Complete
SPOS.MC
Bit 2
Drive in motion
SPOS.MOV
Bit 3
Contouring error/tolerance error
SPOS.DEV
Bit 4
In tolerance
−
Bit 5
Standstill warning
SPOS.STILL
Bit 6
Supply pressure in tolerance
−
Bit 12
Position control is active
−
Bit 13
Standstill control is active
−
Bit 14
Force control is active
−
All bits not mentioned are reserved.
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.
Valve output value
PNU
PNU: 309
Index: 1
Max index: 1
Class: Var
Data type: int32
Values
Without unit
Default: 2047
Minimum: 0
Maximum: 4095
Internal setpoint specifcation for the valve.
Value
Standardised
setpoint value
Ventilation
Venting
Drive moving
4095
−100 %
1 −−> 4
2 −−> 3
... towards smaller actual values
2047
0 %
closed
closed
... not
0
+100 %
1 −−> 2
4 −−> 5
... towards larger actual values
ý
The parameter value cannot be changed.
o
Writing permissible only in commissioning/parametrising mode with disabled controller.
o
This parameter can be written by FCT without higher−order controller.
o
After writing, controller recalculation is carried out.