Festo Контроллер позиционирования CPX-CMAX User Manual

Page 230

background image

5. Parameter

5−42

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Additional axis status

PNU

PNU: 308

Index: 1

Max index: 1

Class: Var

Data type: bitarray

Values

Default:

Write:

Additional status information of the controller.
These are also valid in parametrising mode if SPOS is not available.
Bit 0

Referenced

SPOS.REF

Bit 1

Motion Complete

SPOS.MC

Bit 2

Drive in motion

SPOS.MOV

Bit 3

Contouring error/tolerance error

SPOS.DEV

Bit 4

In tolerance

Bit 5

Standstill warning

SPOS.STILL

Bit 6

Supply pressure in tolerance

Bit 12

Position control is active

Bit 13

Standstill control is active

Bit 14

Force control is active

All bits not mentioned are reserved.

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Valve output value

PNU

PNU: 309

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Without unit

Default: 2047

Minimum: 0

Maximum: 4095

Internal setpoint specifcation for the valve.
Value

Standardised
setpoint value

Ventilation

Venting

Drive moving

4095

−100 %

1 −−> 4

2 −−> 3

... towards smaller actual values

2047

0 %

closed

closed

... not

0

+100 %

1 −−> 2

4 −−> 5

... towards larger actual values

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.