HP 5300 User Manual
Page 138

POST Error Messages
HP Smart Array 5300 Controller User Guide
G-7
HP CONFIDENTIAL
Writer: Jennifer Hayward File Name: q-appg POST messages
Codename: SilverHammer Part Number: 135606-005 Last Saved On: 10/8/02 11:26 AM
Table G-1: POST Error Messages
continued
Message
Description
Meaning and Recommended Action
1779
Slot x drive array – replacement
drive(s) detected or previously failed
drive(s) now appear to be operational:
Port (y): SCSI ID (x)
Restore data from backup if
replacement drive x has been installed.
If this message appears and drive x has not
been replaced, an intermittent drive failure
has occurred. This message also appears
once immediately following drive
replacement before data is restored from
backup.
1783
Slot x drive array controller failure.
If this message appears immediately
following a ROM installation, the ROM is
either defective or not installed properly.
Check that the controller is firmly inserted in
its slot. Check for improper cabling or SCSI
ID conflicts. Try upgrading the system
ROM. Otherwise, replace the array
controller.
1784
Slot x drive array drive failure. The
following SCSI drive(s) should be
replaced:
SCSI port (y) SCSI ID (x)
Check for loose cables. Replace defective
drive x and/or cable(s).
continued