Starting cfggen, Cfggen operation, Rules for creating im volumes and hot spare disks – HP BL860C User Manual
Page 62: Cfggen utility commands
Starting CFGGEN
The
cfggen
utility is located on the HP IPF Offline Diagnostic and Utilities CD. To use
cfggen
:
1.
Insert the CD into the drive.
2.
Boot the server to the EFI Shell prompt.
3.
From the EFI Shell prompt, change to the CD drive:
shell> fs0: Enter
fs0:>
4.
Change to the directory that contains
cfggen.efi
.
fs0:> cd EFI\HP\TOOLS\NETWORK Enter
fs0: EFI\HP\TOOLS\NETWORK>
5.
From this directory, use
cfggen
.
CFGGEN Operation
The
cfggen
command is not case sensitive. You can enter
cfggen
commands and parameters
in uppercase, lowercase, or a mixture of the two. Use the following conventions in command
descriptions:
The
cfggen
command uses a command line interface.
Syntax:
cfggen
Use the following conventions in command descriptions:
•
Text in italics must be entered exactly as shown on the command line.
•
Text surrounded by
< >
must be replaced with a required parameter.
•
Text surrounded by
[ ]
can be replaced by an optional parameter.
•
Parameters surrounded by
{ }
must be entered one or more times, as appropriate for the
issued command.
•
Command line definition characters (
< >
,
[ ]
, and
{ }
) cannot be entered on the command
line.
The program name, controller number, command, and parameters fields must be separated by
the ASCII space character. The format of the parameters is command specific.
The program return value is returned to you when the program exits. A value of
0
is returned if the
command is successful. Otherwise, a value of
1
is returned.
Rules for Creating IM Volumes and Hot Spare Disks
When creating IM volumes and hot spare disks, the following rules apply:
•
All disks that are part of an IM volume or a hot spare for an IM volume must be on the same
SAS controller.
•
IM volumes are supported.
•
Only two IM volumes (plus a global hot spare) per controller can be created.
•
An IM array must have two disks.
•
A hot spare disk cannot be created without at least one IM volume already created.
•
The utility does not allow adding a hot spare disk type different from disk types in the volume.
•
With the
AUTO
command all drives used are the same type as the first available disk found,
and the size is limited to the size of the smallest disk.
CFGGEN Utility Commands
The following are the commands available for the
cfggen
utility.
62
Installing the Server Blade Into the Enclosure