PCI Device

, and

PCI Function

to the

Bus #

,

Dev #

, and

Fnc #

values from the

info io

command.

CAUTION:

Do not change the value for any of these fields on the Adapter Properties screen:

Auto Termination

Parity

Bus Scan Order

Spinup Delay (Secs)

Changing any of these fields can cause unpredictable results.

CAUTION:

Do not change the value for any of these fields on the Device Properties screen:

Scan Id

Scan LUNs > 0

Disconnect

Timeout

Queue Tags

Format

Verify

Changing any of these fields can cause unpredictable results.

7.

Display (and optionally change) any parameters listed below for the channel of the interface,
or restore its parameters to their default values.

ID

Maximum data transfer rate

Bus width

Whether the interface is bootable (driver support)

Avoid bus resets (secondary cluster server)

Restore Defaults

8.

Use the arrow keys to navigate to the appropriate parameter.

9.

Use the plus (+) and minus (-) keys to scroll through the values until the value you want displays.

10. To exit the Adapter Properties screen, press Esc. You are given these choices:

Cancel the exit from the screen (to stay in the Adapter Properties screen for the channel
of the interface)

Save the changes you made and exit the screen

Discard the changes you made and exit the screen

11. Move the cursor to the action (

cancel

,

save

, or

discard

) you want to take; press Enter.

If you selected

cancel

, you remain in the Adapter Properties screen for the channel of the

interface. You can still change the channel’s parameters listed above.
If you selected

save

or

discard

, you go to the EFI Setup Utility main menu.

CAUTION:

Do not select the

option on the main menu.

12. Press Esc to exit the main menu and the EFI Setup Utility.
13. Select the option for exiting the utility.
14. When prompted, press Enter to stop the interface; you are at the EFI Shell prompt.
15. At the EFI Shell prompt, enter the

reset

command. The server starts to reboot. This is required

to cause the new setting.