Supported configurations, System build-up troubleshooting procedure, Supported – HP BL860C User Manual
Page 101
6.
To decode the blinking state of server LED, review the entire SEL and look at events with alert
level 2 and above.
For example:
Log Entry 24: 14 Feb 2003 15:27:02
Alert Level 3: Warning
Keyword: Type-02 1b0800 1771520
Hot Swap Cage: SCSI cable removed
Logged by: BMC; Sensor: Cable / Interconnect - SCSI ChExt Cable
Data1: Device Removed/Device Absent
0x203E4D0AC6020220 FFFF0008F61B0300
Log Entry 73: 00:00:12
Alert Level 3: Warning
Keyword: Type-02 050301 328449
The server's built-in sensors have detected an open chassis door.
Logged by: BMC; Sensor: Physical Security - Chassis Open
Data1: State Asserted
0x200000000C020570 FFFF010302050300
Supported Configurations
This subsection provides examples of how to use the iLO 2 MP to acquire configuration information
for troubleshooting purposes. It also provides a system build-up procedure.
For a list of all FRUs in the server blade, with their corresponding part numbers, see
.
System Build-Up Troubleshooting Procedure
Use this procedure only when the server powers on and remains powered on but does not enter
into or pass POST, or does not boot to EFI menu.
1.
Remove the access panel to gain access to internal FRUs. See
.
2.
Remove all of the HDDs from the front of the chassis. See
.
3.
Remove the memory DIMMs. See
4.
Remove the processors. See
“Removing a Processor” (page 116)
.
5.
Replace the server blade in the enclosure. The server blade (and MP) powers on.
6.
Enter the
DF
command from the MP Console Menu. The following displays:
CM> DF
Display FRU Information Menu:
S - Specific FRU
A - All available FRUs
V - Display Mode: Text
7.
Enter
S
to show the FRU IDs. The following displays:
FRU IDs:
--------
0001-Comm Module 0002-Disk Backplane
0003-Mezzanine Board 0000-Motherboard
If you do not see all of the above FRU IDs, then concentrate on the missing FRU ID(s). The
following alert (IPMI) event displays for this action, as read from the SEL:
Log Entry 4: Dec 2005 00:00:09
Alert Level 7: Fatal
Keyword: Type-02 257100 2453760
Missing FRU device - DIMM0A
Logged by: Baseboard Management Controller,
Supported Configurations
101