Connecting External Storage Systems

Hitachi Universal Storage Platform V/VM Universal Volume Manager User’s Guide

Window Names

Parameters

Parameter Settings

RAM Microprogram Version

You can either specify this parameter or omit
specifying this parameter.

Option

You can either specify this parameter or omit
specifying this parameter.

Operation if the processor
failure occurs

Specify this parameter to Reset of occurred.

WEB Title

You can either specify this parameter or omit
specifying this parameter.

System
Parameter

Write and verify mode

Set this parameter to ON.

Port Options

Port Option

You can either specify this parameter or omit
specifying this parameter.

Host Connection Mode 1

Set this parameter to Standard Mode.

Host Connection
Mode

Host Connection Mode 2

Do not specify any parameters.
Note: Do not specify HISUP OFF mode, either.

Note: You can either specify or omit any other parameters.

Relationship between Serial Number and AMS/WMS Model

When the external storage system is TagmaStore AMS or WMS, you can

identify the storage system model from the serial number displayed in the
Serial Number column in the Volume Operation window.

The following table describes the relationship between serial number displayed
in the Serial Number column and the storage system model.

Table A-2

Relationship between Serial Number and AMS/WMS Model

Storage System

Displayed Serial Number

Model

77XXXXXX AMS

1000

75XXXXXX AMS

500

AMS

73XXXXXX AMS

200

WMS 71XXXXXX WMS

100