Check paths & restore volume – Hitachi MK-96RD626-07 User Manual

Page 129

background image

Performing Universal Volume Manager Operations

5-37

Hitachi Universal Storage Platform V/VM Universal Volume Manager User’s Guide

3. Click the product name in the Volume Operation tree.
4. Right-click the external volume that you want to change in the Volume

Operation list.

5. Click Disconnect Volume in the pop-up menu.

The settings are displayed in blue and italics.

6. Verify the settings in the Preview dialog box.
7. Click Apply in the Volume Operation window.

The settings are applied to the local storage system and the Volume

Operation window is displayed normally. When an error occurs, an error
message is displayed. Verify the details in the Preview dialog box.

Caution: If you want to access the external storage system after you have

executed the Disconnect Volume command, you need to execute the
Check Paths & Restore Volume command.

Checking Connection Status and Resuming External
Volume Operation

You can resume external volume operation by executing the Check Paths &
Restore Volume
command in the following cases:

The Check Paths & Restore Volume command is required to be

executed to resume using the disconnected external volume using the
Disconnect Subsystem command or the Disconnect Volume command.

When the errors occur in all the cross-subsystem paths, the local storage

system makes the status of external volume to Blockade. In this case,
execute the Check Paths & Restore Volume command.
If the status of the external volume cannot be restored even though the

Check Paths & Restore Volume command is executed, restore the path
to the external storage system as described in

Troubleshooting

. Then

execute the Check Paths & Restore Volume command to make the

external volume in the Blockade status usable.

When the Check Paths & Restore Volume command is executed for the

disconnected external volume for which the mapping settings are
preserved, the defined mapping setting and the current status of the
external volume are compared and checked if the settings match the actual

status. The path status and all other mapping configuration definitions are
checked. If the external volume can be resumed as a mapped volume as a
result of the checking processing, the volume status is set to be available

for the I/O operation.