4. Troubleshooting (DeviceNet)


♦ Causes of Error

Possible Cause

Examination Method

Countermeasure

{ Slave power OFF

Measure the power voltage of the
slaves. (It should be within the range
of sufficient voltage for the slave
operation.)
NOTE: For slaves operating with

communications power
supply, measure voltage at
the DeviceNet connector.

Supply power to the
slave.

{ Broken unit

Slave unit replacement

Replace the broken
slave unit with a new
one.

4.1.2.1.2 Slave: Communication Error Detection / Busoff Detection / Not-added

MS

NS

Master LED Condition

Green Light ON

Red Light Blinking

(1) Absent Slave LED Condition

(Communication error detection)

Green Light ON

Red Light Blinking

(2) Absent Slave LED Condition

(Busoff detection)

Green Light ON

Red Light ON

(3) Absent Slave LED Condition

(Slave not added to the network)

Green Light ON

Light OFF

Fieldbus I/O Rev.6

83