beautypg.com

6 epson rc+ master configuration – Epson EM07ZS1647F User Manual

Page 148

background image

4. Troubleshooting (PROFIBUS DP)

4.2.3.6 EPSON RC+ Master Configuration

For details of EPSON RC+ master configuration, refer to the section 2.6 PROFIBUS DP
Board Installation
.

The following section describes the procedure for verifying the scanner board condition with
the applicomIO Console application.

4.2.3.6.1 Verifying applicomIO Console application condition

The status bar at the bottom of the window shows the applicomIO Console
application status. The status bar varies as shown below:

Character:

The address number of the scanner board is indicated with

characters. When the character “F” appears, the flash
memory on the board initialized the scanner board.

Background color: The background color indicates the scanner board status. For

details, refer to the table below.

Background Character

Status

Gray Black

Access to scanner board was failed.
After that, the status bar will not be renewed
automatically. To renew the status bar, right-click
the status bar and select Refresh.

Magenta

Black

The scanner board was initialized with the earlier
version applicomIO Console application.
It is recommended that the scanner board be written
into the flash memory (reinitializing the scanner
board) again with the current version applicomIO
Console application.

Red

Black

The scanner board was not initialized.
Initialize the scanner board to use it.

Yellow

Black

The scanner board was partially initialized.
This status happens only during network detection
and on-line actions.

Deep green

White

Although the scanner board was initialized, it is
different with the currently opened configuration.
(Different version, etc.)
It is recommended that the scanner board be written
into the flash memory (reinitializing the scanner
board) again with the current version applicomIO
Console application.
This status happens only during network detection,
on-line actions, and diagnostic.

Green

Black

The scanner board was initialized properly and it is
no different with the currently opened configuration.
This status happens only during network detection,
on-line actions, and diagnostic.

136

Fieldbus I/O Rev.6