4. Troubleshooting (EtherNet/IP)

4.3.2 Problems and Countermeasures

Master Unit LED

MS NS

Error Description

[Reference]

Green
Light ON

Green
Light ON

Normal
communication

- Normal condition

Green
Light ON

Green
Light
Blinking

During connection
establishment

- Processing connection establishment

(The NS LED will be ON in green in a few seconds.)

- Master function in stop state

(Communication does not start.)

Green
Light ON

Red Light
Blinking

Communication
timeout

- Network channel error

Green
Light ON

Light OFF IP address not

defined

- The IP address is not defined

Red Light
Blinking

No Matter

Critical error

[Refer to the section 4.3.3 Tests and diagnostics.]

- Unrecoverable critical error

Red Light
ON

No Matter

Module error

[Refer to the section 4.3.3 Tests and diagnostics.]

- Recoverable error occurred

Light OFF No Matter

error

[Refer to the section 4.1.2.5 Absent Slave.]

- No slave (Error detection before communication

establishment)

- Communications power supply OFF

Light OFF Light OFF Not initialized status [Refer to the section 2.9.5 Master Mode and 2.9.6

Slave Mode.]

- The communication board is not initialized
Check the configuration

Fieldbus I/O Rev.6