Vivotek NR9682-v2 64-Channel NVR (No HDD) User Manual
Page 146
![background image](https://www.manualsdir.com/files/886546/content/doc146.png)
VIVOTEK - A Leading Provider of Multimedia Communication Solutions
146 - User's Manual
For I/O box configuration, please refer to the I/O Box page.
3. I/O box and TCP triggers
DI/DO Device DI
This applies when an external I/O box is applied, e.g., Advantech's ADAM
I/O box.
DI/DO Device DO
TCP Message
TCP message comes from the peer VAST servers or external
sources (such as an access control system) via the analysis of
received TCP message over the 3444 port. This is a paid feature.
Data Magnet
Triggering conditions can be acquiring data from 3rd-party software,
such as the character height, image width, list, list name, country,
from an LPR software, etc.
To configure a TCP message trigger,
Select TCP message as a trigger type, and enter a description, such as a short term, for VAST
to listen and analyze data packages.
You can use Telnet to send a small amount of data matching the term you entered in the TCP
message configuration window. A TCP message event will be triggered, and you should see the
event prompt as follows.
Below are the messaging parameters:
1.
text contains
: Messages will be
received if some of the textual
messages match the keywords.
2.
text matches
: Textual messages must
be exactly identical.
3.
Case sensitive
: The upper or lower
cases letters used in the messages
must match within the messages.