Connecting remote controllers, cameras, and setup PC using LAN connection

Connection example

1

Connect the LAN connector of the units
and LAN connector of the cameras using
LAN cables.

You can connect up to 100 cameras and five remote
controllers on the same network.

2

To configure setting of the unit and
cameras using setup software, connect a
PC to the same network.

• Use shielded-type LAN cables to prevent

malfunction that may result from radiation noise.

• Use a LAN cable (category 5 or higher).
• Connect the cameras, remote controllers, and PC

via switching hubs (10BASE-T or 100BASE-
TX). Use on a network with significant packet
loss or delay may cause a malfunction. Use a
high-quality network.

• Do not mix 10BASE-T and 100BASE-TX in the

network.

EXT SYNC IN

TERMI-
NATION

ON OFF

ON

ON

OFF

LINE OUT

SDI 1

OSD

LAN

SDI 2

2 3 4 5 6 7 8

1

MONITOR OUT

HDMI OUT

SDI 1

SDI 2

IN

SYSTEM
SELECT

IR SELECT

CAMERA SETUP

1 2 3

VISCA RS - 422 OUT

12V

HDMI OUT

SDI OUT

SYSTEM
SELECT

MIC

R

L

(PLUG IN POWER)

VISCA RS-422

IR SELECT

LAN

MODE

VISCA

1

9

1

9

RS-422

TALLY/CONTACT

RS-232C

!

DC 12V

LAN

RGB/COMPONENT

VISCA RS-422

1 2 3 4 5 6 7 8

9

EXT SYNC IN

IR SELECT

75

1 2 3

OFF

ON

HD

SD

IN VISCA RS-232 OUT

SDI OUT

DC IN 12V

R

VIDEO

S VIDEO

SDI OUT

LAN

1

2

BRBK-IP10

ON

HD

SD

OFF

DATA MIX

BAUD RATE

RM-IP500

BRC-H900

BRBK-IP10
IP control card

*3

RM-IP10

Switching hub

BRC-X1000,
BRC-H800

Video switcher

*1

SRG-360SHE

Setup PC

Video monitor

Remote control signal: LAN cable (category 5 or higher)

Tally/contact signal: Connection cable

*2

Video signal: HDMI cable

Video signal: Connection cable with BNC connectors

Signal flow

*1 For an example connection with a video switcher, see “Connection with a video switcher” (page 25).
*2 Use a connection cable designed for the switcher being used. For the specifications of the GPI I/O connector of

the unit, see “Pin assignments” (page 59).

*3 To connect the BRC-H900 using a LAN connection, a BRBK-IP10 IP control card must be installed. In addition,