Label ID: Set Individually Per Symbology
To configure a Label ID individually for a single symbology:
1. Scan the ENTER/EXIT bar code.
2. Select Label ID position as either BEFORE (Enable as Prefix) or AFTER (Enable as suf-
fix) by scanning the appropriate bar code in the section
.
for Label ID positioning options if multiple identification features are
enabled.
3. Scan a bar code to select the symbology for which you wish to configure a custom Label
Label ID Symbology Selection, starting on page 72
.
4. Determine the desired character(s) (you may choose up to three) which will represent the
Label ID for the selected symbology.
5. Turn to the
on the inside back cover of this manual and find the equivalent
hex digits associated with your choice of Label ID. For example, if you wish to select an
equal sign (=) as a Label ID, the chart indicates its associated hex characters as 3D. Turn to
and scan the bar codes representing the hex characters
determined. For the example given, the characters ‘3’ and ‘D’ would be scanned. More
examples of Label ID settings are provided in
.
6. Scan the ENTER/EXIT bar code to exit Label ID entry.
7. Scan the ENTER/EXIT bar code once again to exit Programming Mode.
This completes the steps to configure a Label ID for a given symbology.
Figure 9. Label ID Position Options
NOTE
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again at
the beginning.
OR
Prefix
Suffix
Label ID
Label ID
Bar Code Data
Aim ID