Default, Code 39 — cont, Code 39 check character transmission – Datalogic QuickScan Lite QW2100 User Manual
Page 139: Code 39 start/stop character transmission
Code 39
Product Reference Guide
129
ENTER/EXIT PROGRAMMING MODE
Code 39 Check Character Transmission
Enable this option to transmit the check character along with Code 39 bar code data.
Code 39 Start/Stop Character Transmission
Enable this option to enable/disable transmission of Code 39 start and stop characters.
$CC3CT00
Code 39 Check Character Transmission = Don’t Send
$CC3CT01
Code 39 Check Character Transmission = Send
DEFAULT
$CC3SS00
Code 39 Start/Stop Character Transmission = Don’t Trans-
mit
$CC3SS01
Code 39 Start/Stop Character Transmission = Transmit
DEFAULT