Symbologies

242

QuickScan

TM

Lite QW2100

ENTER/EXIT PROGRAMMING MODE

BC412 — cont.

BC412 Set Length 2

This feature specifies one of the bar code lengths for

BC412 Length Control

. Length 2 is the

maximum label length if in

Variable Length

Mode, or the second fixed length if in

Fixed

Length

Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The

length does not include start/stop characters.

The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length
(only one fixed length). See

Set Length 2 on page 269

for more detailed programming

instructions.

$CBCL2

Select Code 39Length 2 Setting

Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

50 = Length 2 is 50 Characters